LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE

Marke: LENOVO | Numer produktu: 6411-HC1
  • Nicht auf Lager
LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE
25.199,99 zł
zzgl. MwSt.
local_shipping W dostawie : 3 - 5 days
Stan: Używane help_outline
Gwarancja:  1 rok
 

Security Policy

 

Delivery Policies

 

Return Policies

Menge
Nicht auf Lager

  • Wysyłamy na cały świat
  • Wszystkie przedmioty wysyłane z naszego magazynu
  • Łatwe i szybkie zamawianie 24/7
  • Ekspresowa wysyłka międzynarodowa w 24h
  • Ekspresowa dostawa wynosząca nawet 1-2 dni roboczych
Jeśli zamówisz teraz wyślemy następnego dnia roboczego
Jeśli zamówisz teraz wyślemy za:
godzin
minut
sekund
Opis

LENOVO STORAGE S2200 12 BAY LFF CONTROLLER ENCLOSURE 6411-HC1
 
Specification


Manufacturer part number 6411-HC1
ModelS2200
Brand Lenovo
Product type Storage
Form factor Rack mountable 2U
Include 2 x Lenovo 595W power supply for S2200
2 x Lenovo storage FC/ISCSI RAID controller for S2200
RAID levels RAID 1, 5, 6, 10
Drive bays Up to 96 SFF drive bays per system:
  - 24 SFF drive bays in the S2200 controller enclosure
  - 24 SFF drive bays in the E1024 drive expansion enclosure; up to 3x E1024 enclosures

Up to 48 LFF drive bays per system:
  - 12 LFF drive bays in the S2200 controller enclosure
  - 12 LFF drive bays in the E1012 drive expansion enclosure; up to 3x E1012 enclosures

Intermix of SFF and LFF enclosures is supported.
Drive technologies SAS and NL SAS HDDs and SEDs; eMLC SAS SSDs. Intermix of HDDs and SSDs is supported. Intermix of SEDs with HDDs or SSDs is not supported.
Drive connectivity Dual-ported 6 Gb SAS drive attachment infrastructure.

Controller enclosure with one or two RAID controllers (ports per one controller):
  - 24x 6 Gb SAS internal drive ports (SFF chassis)
  - 12x 6 Gb SAS internal drive ports (LFF chassis)
  - 1x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion port for the attachment of the external drive enclosures

Drive expansion enclosure with one or two expansion modules (ports per one module):
  - 24x 6 Gb SAS internal drive ports (SFF chassis)
  - 12x 6 Gb SAS internal drive ports (LFF chassis)
  - 2x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion ports (IN and OUT) for the daisy chained attachment of the external drive enclosures
Drives SFF drives:
  - 400 GB, 800 GB, and 1.6 TB SAS SSDs (3 DWD and 10 DWD)
  - 400 GB and 800 GB SAS SED SSDs (10 DWD)
  - 3.84 TB SAS SSDs (1 DWD)
  - 300 GB and 600 GB 15K rpm SAS HDDs
  - 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
  - 1 TB and 2 TB 7.2K rpm NL SAS HDDs

LFF drives:
  - 400 GB SAS SSDs (10 DWD)
  - 600 GB and 900 GB 10K rpm SAS HDDs
  - 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm NL SAS HDDs
Storage capacity Up to 480 TB (48x 10 TB NL SAS HDDs)
Host connectivity S2200 FC and iSCSI controller: 2x SFP/SFP+ CNC host ports
CNC host port options (per RAID controller):
  - 2x 1 Gb iSCSI SFP (1 Gb speed, UTP, RJ-45)
  - 2x 10 Gb iSCSI SFP+ (1/10 Gb speeds, SW fiber optics, LC)
  - 2x 8 Gb FC SFP+ (4/8 Gb speeds, SW fiber optics, LC)
  - 2x 10 Gb iSCSI SFP+ DAC cables
Performance Dual controller configuration:
  - Up to 80,000 random read IOPS (4 KB blocks)
  - Up to 3.3 GBps sequential read throughput (512 KB blocks)
  - Up to 2.4 GBps sequential write throughput (512 KB blocks)
Configuration maximums Per system:
  - Maximum number of virtual storage pools: 2 (1 per controller)
  - Maximum number of logical volumes (total/mapped): 2,048/1,024
  - Maximum logical volume size: 128 TB
  - Maximum number of drives in a drive group: 16
  - Maximum number of drive groups: 32
  - Maximum global spares: 16
  - Maximum number of initiators: 8,192 (1,024 per port)
  - Maximum number of hosts in a host group: 256
  - Maximum number of host groups: 32
  - Maximum number of initiators per host: 128
Gwarancja

Produkt objęty jest roczną gwarancją. Jeśli potrzebują Państwo przedłużenia opieki gwarancyjnej lub jej rozszerzenia, prosimy o kontakt.
Opinie

Kontakt

Masz pytania lub potrzebujesz dodatkowych informacji o produkcie? Skontaktuj się z nami! Jesteśmy tutaj, aby pomóc.

Nasza obsługa klienta chętnie odpowie na Twoje pytania i pomoże w dokonaniu najlepszego wyboru.